The lock will be locked as soon as the door monitor indicates that the door has been opened. The door monitor gives the door closed signal when the circuit is closed.Ĭancel access time once door is opened – Select to prevent tailgating. The door monitor gives the door open signal when the circuit is open. Open circuit = Open door – Select if the door monitor circuit is normally closed. The door monitor gives the door closed signal when the circuit is open. The door monitor gives the door open signal when the circuit is closed. Open circuit = Closed door – Select if the door monitor circuit is normally open. Deselect if no door monitor will be used. Each door has its own door monitor that, for example, will signal when the door has been forced open or open too long. The following door monitor options are available:ĭoor monitor – Selected by default.